Publications and Research

Document Type

Poster

Publication Date

Fall 10-9-2011

Abstract

Test boring associated with the recently accomplished City Water Tunnel # 3 in Manhattan, New York City revealed moderately to highly weathered marble with insoluble silicate residues composed mostly of phlogopite, chlorite, and tremolite. Apparent control on the weatherability of the marble was in response to original mineral constituents dominating this lithology. Encountered marble samples ranged between pure calcitic to mixed dolomitic/siliceous types. Fresh marble samples collected from adjacent boring locations revealed characteristic geochemical data: Lime (25-45%), Silica (4-7%), Alumina (1-3%), MgO (5-20%), and LOI (35-42%); compressive strength of unweathered marble varied between 2000-3000 Kg/cm2. Relict foliations with schistose in nature were also noted in some marbles. Geotechnical characteristics such as sudden decrease in N-value (blow counts), faster drilling rate, and poor RQD (Rock Quality Designation) associated with this weathered zone also suggested incompetent and unconsolidated rock debris. Both physical and geotechnical attributes of the marble indicated the existence of dissolution-controlled subsurface conditions. Although the probability is low, deep voids in the marble in Lower Manhattan could cause problems if the tunnel boring operation intersects them. Usually, solution voids in carbonates do not occur at such depth, unless there is the presence of intricate joint or fracture systems, which continue deep within the subsurface rocks. However, faulting, in and around Canal Street, could create just such a situation. Possible occurrences of complex and perhaps interconnected fractures, enlarged by solution within the marble, may create an easy passageway for water flow. Moreover, it appears that such a void was encountered by a test boring on Bowery Street just south of Canal Street at a depth of about 200 feet. If a water filled void, which is part of an interconnected fracture system, is encountered during the tunnel boring, then water could enter the tunnel at a rate that would be difficult to control. From the test boring data, it appears that the present, proposed tunnel alignment is well west of the major occurrence of the marble. Nevertheless, it would be prudent to be alert to signs of excessive water entering the tunnel, particularly during the probe drilling operations.

Comments

This poster was presented at the Geological Society of America 2011 Annual Meeting & Exposition in Minneapolis, Minnesota.

Corresponds to Geological Society of America Abstracts with Programs. Vol. 43, No. 5, p.129

Share

COinS
 
 

To view the content in your browser, please download Adobe Reader or, alternately,
you may Download the file to your hard drive.

NOTE: The latest versions of Adobe Reader do not support viewing PDF files within Firefox on Mac OS and if you are using a modern (Intel) Mac, there is no official plugin for viewing PDF files within the browser window.